ON-BOARD DIAGNOSTIC SYSTEM FAIL-SAFE FUNCTION [TCM (SJ6A-EL)]
Purpose/Function
If a transmission malfunction is detected by the malfunction detection function, the fail-safe function limits the transmission control.
Even if the transmission has a malfunction, the fail-safe function assures the minimum vehicle driveability.
Construction/Operation
DTC separate fail-safe function—: Not applicable DTC No. |
Description |
Fail-safe function |
P0601:00 |
TCM: ROM check sum error |
|
P0603:00 |
TCM: EEPRPM check sum error |
— |
P0604:00 |
TCM: RAM access error |
|
P0707:00 |
TR switch: Short circuit |
|
P0708:00 |
TR switch: Open circuit |
|
P0711:00 |
TFT sensor: Sensor malfunction |
|
P0712:00 |
TFT sensor: Short to ground |
|
P0713:00 |
TFT sensor: Open circuit |
|
P0717:00 |
Turbine sensor: No signal input |
|
P0722:00 |
VSS: No signal input |
|
P0751:00 |
Shift solenoid A: Stuck off |
|
P0752:00 |
Shift solenoid A/shift solenoid D: Stuck on |
|
P0756:00 |
Shift solenoid B: Stuck off |
|
P0757:00 |
Shift solenoid B: Stuck on |
|
P0761:00 |
Shift solenoid C: Stuck off |
|
P0762:00 |
Shift solenoid C: Stuck on |
|
P0766:00 |
Shift solenoid D: Stuck off |
|
Shift solenoid G: Stuck on |
||
P0781:00 |
1-2 shift valve |
|
P0813:00 |
Reverse sequence valve |
|
P0819:00 |
M position switch up or down switch signal: Signal error |
|
P0882:00 |
Power supply voltage: Low input |
|
P0961:00 |
Line pressure control solenoid signal: Solenoid stuck |
|
P0962:00 |
Line pressure control solenoid signal: Open/short circuit |
|
P0963:00 |
Line pressure control solenoid signal: Short circuit |
|
P0969:00 |
Shift solenoid F: Solenoid stuck |
|
P0970:00 |
Shift solenoid F signal: Open/short circuit |
|
P0971:00 |
Shift solenoid F signal: Short circuit |
|
P0973:00 |
Shift solenoid A signal: Short circuit |
|
P0974:00 |
Shift solenoid A signal: Open/short circuit |
|
P0976:00 |
Shift solenoid B signal: Short circuit |
|
P0977:00 |
Shift solenoid B signal: Open/short circuit |
|
P0979:00 |
Shift solenoid C signal: Short circuit |
|
P0980:00 |
Shift solenoid C signal: Open/short circuit |
|
P0982:00 |
Shift solenoid D signal: Short circuit |
|
P0983:00 |
Shift solenoid D signal: Open/short circuit |
|
P0985:00 |
Shift solenoid E signal: Short circuit |
|
P0986:00 |
Shift solenoid E signal: Open/short circuit |
|
P2719:00 |
Shift solenoid G: Solenoid stuck |
|
P2720:00 |
Shift solenoid G signal: Open/short circuit |
|
P2721:00 |
Shift solenoid G signal: Short circuit |
|
P2757:00 |
TCC: Stuck off |
|
P2758:00 |
TCC: Stuck on |
|
P2762:00 |
TCC control solenoid signal: Solenoid stuck |
|
P2763:00 |
TCC control solenoid signal: Short circuit |
|
P2764:00 |
TCC control solenoid signal: Open/short circuit |
|
U0073:00 |
CAN communication: Module communication error |
|
U0074:00 |
CAN communication: Module communication error (local CAN between TCM and PCM) |
|
U0100:00 |
CAN communication: Communication error between PCM |
— |
U0115:00 |
CAN communication: Communication error between PCM (local CAN between TCM and PCM) |
|
U0121:00 |
CAN communication: Communication error between DSC HU/CM |
|
U0131:00 |
CAN communication: Communication error between EPS control module |
— |
U0155:00 |
CAN communication: Communication error between instrument cluster |
|
U0214:00 |
CAN communication: Communication error between start stop unit |
|
U0442:00 |
CAN communication: Error signal received from PCM |
|
Emergency Mode
Emergency mode shifts as follows when in D or R position.
Condition |
Selector lever position |
||||||
D position |
R position |
||||||
Normal shifting |
1GR |
2GR |
3GR |
4GR |
5GR |
6GR |
Reverse |
When there is any malfunction in shift solenoids A, B, C, D, E, F, G, or line pressure control solenoid |
4GR |
Reverse |