VACUUM SENSOR 1 INSPECTION
1. Connect the M-MDS to the DLC-2.
2. After the vehicle is identified, select the following items from the initialization screen of the M-MDS.a. Select “DataLogger”.b. Select “Modules”.c. Select “EVP”.
3. Select the monitor item “VS1“ from the PID table.
4. Verify that the monitor value of monitor item “VS1“ is 40 kPa {300 mmHg, 12 inHg} or less.< Previous Next >
If the monitor value is not 40 kPa {300 mmHg, 12 inHg} or less, replace the power brake unit. (See POWER BRAKE UNIT REMOVAL/INSTALLATION.)