ELECTRIC VARIABLE VALVE TIMING CONTROL [SKYACTIV-G 2.0]
Outline
The PCM determines the optimum intake valve timing according to the engine operation conditions, and sends the motor drive signals to the electric variable valve timing driver. With the adoption of the electric drive system, variable intake valve timing can be controlled without any influence from the engine conditions, thus the fuel economy has been improved and pumping loss has been decreased.
Based on the coordination with the hydraulic variable valve timing control and by increasing the amount of overlap during high engine loads, nitrogen oxide (NOx) occurring largely at high temperatures is reduced by re-circulating exhaust gas into the combustion chamber which reduces combustion temperature.
Block Diagram
Operation
Intake valve timing determination
The PCM determines the optimum target intake valve timing according to the engine operation conditions, and controls the output duty ratio to the electric variable valve timing driver so that the actual intake valve timing approaches close to the target intake valve timing.
Target valve timing
The target intake valve timing is determined according to the engine speed, charging efficiency, and engine coolant temperature.
Actual valve timing
The actual intake valve timing is calculated by adding a correction, which is based on the electric variable valve timing actuator signal value, to the value calculated by subtracting the cam maximum retard learning value from the standard intake valve timing.
The standard intake valve timing is calculated based on the signals from the CKP and CMP sensors.
Cam maximum retard learning value
The cam maximum retard learning value is determined by the maximum retard indication output from the PCM and the standard intake valve timing when the standard intake valve timing is stabilized.
Output duty ratio determination
The PCM divides the electric variable valve timing motor drive range modes according to the engine operation conditions, and determines the output duty ratio to the electric variable valve timing actuator in each mode.
Mode name |
Control description |
Control conditions |
Feedback mode |
|
|
Energization cut mode |
|
|
Phase holding mode |
|
|