AIR INTAKE MODE DOES NOT CHANGE [CLIMATE CONTROL SYSTEM]
| DESCRIPTION |
|
| POSSIBLE CAUSE |
|
When performing an asterisked (*) troubleshooting inspection, shake the wiring harness and connectors while performing the inspection to discover whether poor contact points are the cause of any intermittent malfunctions. If there is a problem, inspect to make sure connectors, terminals and wiring harnesses are connected correctly and undamaged.
Diagnostic Procedure
| Step |
Inspection |
Action |
|
| 1 |
INSPECT AIR INTAKE ACTUATOR
|
Yes |
Go to Step 7. |
| No |
Go to the next step. |
||
| 2 |
INSPECT TO SEE WHETHER MALFUNCTION IS IN AIR INTAKE ACTUATOR OR ELSEWHERE
|
Yes |
Go to the next step. |
| No |
Go to Step 4. |
||
| 3 |
INSPECT AIR INTAKE ACTUATOR
|
Yes |
Go to Step 7. |
| No |
Replace the air intake actuator. (See AIR INTAKE ACTUATOR REMOVAL/INSTALLATION [FULL-AUTO AIR CONDITIONER].) (See AIR INTAKE ACTUATOR REMOVAL/INSTALLATION [MANUAL AIR CONDITIONER].) Then go to Step 9. |
||
| 4 |
INSPECT TO SEE WHETHER MALFUNCTION IS IN WIRING HARNESS (SHORT TO B+ BETWEEN CLIMATE CONTROL UNIT AND AIR INTAKE ACTUATOR) OR ELSEWHERE
|
Yes |
Go to the next step. |
| No |
Refer to the wiring diagram and verify whether or not there is a common connector between climate control unit terminal and air intake actuator terminal.
Go to Step 9. |
||
| 5 |
INSPECT TO SEE WHETHER MALFUNCTION IS IN WIRING HARNESS (SHORT TO GROUND BETWEEN CLIMATE CONTROL UNIT AND AIR INTAKE ACTUATOR) OR ELSEWHERE
|
Yes |
Refer to the wiring diagram and verify whether or not there is a common connector between climate control unit terminal and air intake actuator terminal.
Go to Step 9. |
| No |
Go to the next step. |
||
| 6 |
INSPECT TO SEE WHETHER MALFUNCTION IS IN WIRING HARNESS (LACK OF CONTINUITY OR OPEN BETWEEN CLIMATE CONTROL UNIT AND AIR INTAKE ACTUATOR) OR ELSEWHERE
|
Yes |
Replace the climate control unit, then go to Step 9. (See CLIMATE CONTROL UNIT REMOVAL/INSTALLATION [FULL-AUTO AIR CONDITIONER].) (See CLIMATE CONTROL UNIT REMOVAL/INSTALLATION [MANUAL AIR CONDITIONER].) |
| No |
Refer to the wiring diagram and verify whether or not there is a common connector between climate control unit terminal and air intake actuator terminal.
Go to Step 9. |
||
| 7 |
INSPECT AIR INTAKE LINK
|
Yes |
Go to the next step. |
| No |
Apply grease to the links. If any the links are damaged, replace the air intake actuator, then go to Step 9. |
||
| 8 |
INSPECT TO SEE WHETHER MALFUNCTION IS IN CLIMATE CONTROL UNIT OR AIR INTAKE DOOR
|
Yes |
Go to the next step. |
| No |
Remove obstruction, or install the doors in the proper position. If any doors are cracked or damaged, replace them, then go to the next step. |
||
| 9 |
VERIFY THAT MALFUNCTION SYMPTOMS DO NOT RECUR AFTER REPAIR
|
Yes |
Troubleshooting completed. Explain repairs to customer. |
| No |
Recheck malfunction symptoms, then repeat from Step 1 if the malfunction recurs. |
||