NO COOL AIR [CLIMATE CONTROL SYSTEM]

DESCRIPTION

  • Magnetic clutch does not operate

POSSIBLE CAUSE

  • Airflow mode system malfunction

  • Blower system malfunction

  • A/C compressor malfunction

  • CAN communication malfunction

  • PCM A/C cut control system malfunction

  • Refrigerant pressure sensor malfunction

  • Evaporator temperature sensor malfunction

  • Magnetic clutch malfunction

  • A/C MAG 7.5 A fuse malfunction

  • A/C relay malfunction

  • Improper refrigerant charging amount

  • When performing an asterisked (*) troubleshooting inspection, shake the wiring harness and connectors while performing the inspection to discover whether poor contact points are the cause of any intermittent malfunctions. If there is a problem, check to make sure connectors, terminals and wiring harnesses are connected correctly and undamaged.

Diagnostic Procedure

Step

Inspection

Action

1

INSPECT AIR BLOW OUT
  • Does air blow out?

Yes

Go to the next step.

No

Go to Step 1 of the following troubleshooting.

(See INSUFFICIENT AIR (OR NO AIR) BLOWN FROM VENTS [CLIMATE CONTROL SYSTEM].)

(See AMOUNT OF AIR BLOWN FROM VENTS DOES NOT CHANGE [CLIMATE CONTROL SYSTEM].)

2

INSPECT A/C COMPRESSOR OPERATION
  • Start engine.

  • Turn A/C switch and fan switch on.

  • Does A/C compressor operate?

Yes

Go to Step 1 of the following troubleshooting.

AIR FROM VENTS NOT COLD ENOUGH [CLIMATE CONTROL SYSTEM]

No

Go to the next step.

3

INSPECT FOR DTCs IN PCM, CLIMATE CONTROL UNIT, AND INSTRUMENT CLUSTER
  • Inspect for DTCs related to the PCM, climate control unit, and instrument cluster on-board diagnostic system.

    (See ON-BOARD DIAGNOSTIC TEST [PCM (SKYACTIV-G 2.0)].)

    (See DTC DISPLAY [CLIMATE CONTROL UNIT (FULL-AUTO AIR CONDITIONER)].)

    (See DTC DISPLAY [CLIMATE CONTROL UNIT (MANUAL AIR CONDITIONER)].)

  • Are any DTCs displayed?

Yes

Go to appropriate inspection procedure.

(See DTC TABLE [PCM (SKYACTIV-G 2.0)].)

(See DTC TABLE [CLIMATE CONTROL UNIT (FULL-AUTO AIR CONDITIONER)].)

(See DTC TABLE [CLIMATE CONTROL UNIT (MANUAL AIR CONDITIONER)].)

(See DTC TABLE [INSTRUMENT CLUSTER].)

No

Go to the next step.

4

DETERMINE IF MALFUNCTION CAUSE IS A/C REQUEST SIGNAL OR A/C RELAY OPERATIONAL MALFUNCTION
  • Access PCM PID ACCS using the M-MDS.

    (See OBD-II PARAMETER IDENTIFICATION (PID) ACCESS [PCM (SKYACTIV-G 2.0)].)

  • Start the engine and idle it.

  • Turn the PID ACCS to ON from OFF using the M-MDS simulation function.

  • Is the magnetic clutch engaged?

Yes

Go to the next step.

No

Go to Step 9.

5

DETERMINE IF MALFUNCTION CAUSE IS REFRIGERANT PRESSURE SENSOR SIGNAL OR ELSEWHERE
  • Access climate control unit PID AC_PRES.

    (See OBD-II PARAMETER IDENTIFICATION (PID) ACCESS [PCM (SKYACTIV-G 2.0)].)

  • Monitor the AC_PRES PID while turning on and off the air conditioner by switching the control panel.

  • Is the PID normal?

Yes

Go to Step 7.

No

Go to the next step.

6

INSPECT REFRIGERANT PRESSURE SENSOR
  • Inspect the refrigerant pressure sensor.

    (See REFRIGERANT PRESSURE SENSOR INSPECTION [FULL-AUTO AIR CONDITIONER].)

    (See REFRIGERANT PRESSURE SENSOR INSPECTION [MANUAL AIR CONDITIONER].)

  • Is the refrigerant pressure sensor normal?

Yes

Inspect the following and repair or replace if necessary.

  • Refrigerant charging amount

  • A/C compressor for seizure

Then go to Step 15.

No

Repair or replace malfunctioning part according to inspection result, then go to Step 15.

7

DETERMINE IF MALFUNCTION CAUSE IS EVAPORATOR TEMPERATURE SENSOR OPERATIONAL SIGNAL OR ELSEWHERE
  • Access climate control unit PID EVA_TMP_SEN.

    (See PID/DATA MONITOR DISPLAY [CLIMATE CONTROL UNIT (FULL-AUTO AIR CONDITIONER)].)

  • Monitor the EVA_TMP_SEN PID while turning on and off the air conditioner by switching the control panel.

    (See PID/DATA MONITOR TABLE [CLIMATE CONTROL UNIT (FULL-AUTO AIR CONDITIONER)].)

    (See PID/DATA MONITOR TABLE [CLIMATE CONTROL UNIT (MANUAL AIR CONDITIONER)].)

  • Is the PID normal?

Yes

Go to Step 9.

No

Go to the next step.

8

INSPECT EVAPORATOR TEMPERATURE SENSOR
  • Inspect the evaporator temperature sensor.

    (See EVAPORATOR TEMPERATURE SENSOR INSPECTION [FULL-AUTO AIR CONDITIONER].)

    (See EVAPORATOR TEMPERATURE SENSOR INSPECTION [MANUAL AIR CONDITIONER].)

  • Is the evaporator temperature sensor normal?

Yes

Refer to the wiring diagram and verify whether or not there is a common connector between evaporator temperature sensor terminal and climate control unit terminal.

    If there is a common connector:
  • Determine the malfunctioning part by inspecting the common connector and the terminal for corrosion, damage, or pin disconnection, and the common wiring harness.

  • Repair or replace the malfunctioning part.

    If there is no common connector:
  • Repair or replace the wiring harness.

Go to Step 15.

No

Replace the evaporator temperature sensor, then go to Step 16.

(See A/C UNIT DISASSEMBLY/ASSEMBLY.)

9*

INSPECT TO SEE WHETHER MALFUNCTION (LACK OF CONTINUITY) IS IN A/C CONTROL SIGNAL CIRCUIT (BETWEEN A/C RELAY AND PCM) OR ELSEWHERE
  • Does cool air blow out when terminal E of A/C relay connector (A/C control signal) is grounded?

Yes

Release short, then go to the next step.

No

Go to Step 11.

10*

INSPECT TO SEE WHETHER MALFUNCTION (LACK OF CONTINUITY) IS IN PCM OR WIRING HARNESS (BETWEEN A/C RELAY AND PCM)
  • Test voltage at the A/C relay control signal terminal of PCM.

  • Is voltage approx. 12 V?

Yes

Inspect the PCM, then go to Step 15.

(See PCM INSPECTION [SKYACTIV-G 2.0].)

No

Refer to the wiring diagram and verify whether or not there is a common connector between A/C relay terminal and PCM terminal.

    If there is a common connector:
  • Determine the malfunctioning part by inspecting the common connector and the terminal for corrosion, damage, or pin disconnection, and the common wiring harness.

  • Repair or replace the malfunctioning part.

    If there is no common connector:
  • Repair or replace the wiring harness.

Go to Step 14.

11

INSPECT TO SEE WHETHER MALFUNCTION IS IN MAGNETIC CLUTCH OR ELSEWHERE
  • Inspect the magnetic clutch.

    (See MAGNETIC CLUTCH INSPECTION.)

  • Is the magnetic clutch normal?

Yes

Go to the next step.

No

Replace the magnetic clutch, then go to Step 15.

(See MAGNETIC CLUTCH DISASSEMBLY/ASSEMBLY.)

12

INSPECT FUSE
  • Remove the A/C MAG 7.5 A fuse.

  • Is the fuse normal?

Yes

Go to the next step.

No

Replace the A/C MAG 7.5 A fuse, then go to Step 16.

If fuse burns out immediately, go to the next step.

13

INSPECT WIRING HARNESS BETWEEN FUSE BLOCK AND A/C RELAY FOR LACK OF CONTINUITY
  • Test voltages at following terminals of A/C relay.

    • Terminal A (A/C relay control signal)

    • Terminal C (A/C control signal)

  • Are voltages approx. 12 V?

Yes

Go to the next step.

No

Refer to the wiring diagram and verify whether or not there is a common connector between fuse block terminal and A/C relay terminal.

    If there is a common connector:
  • Determine the malfunctioning part by inspecting the common connector and the terminal for corrosion, damage, or pin disconnection, and the common wiring harness.

  • Repair or replace the malfunctioning part.

    If there is no common connector:
  • Repair or replace the wiring harness.

Go to Step 15.

14

INSPECT TO SEE WHETHER MALFUNCTION IS IN A/C RELAY OR WIRING HARNESS (BETWEEN A/C RELAY AND MAGNETIC CLUTCH)
  • Test voltage at the following terminal of A/C relay.

    • Terminal D (magnetic clutch operation signal)

  • Is voltage approx. 12 V?

Yes

Inspect wiring harness between A/C relay and magnetic clutch.

  • If above wiring harness is normal, go to the next step.

  • If above wiring harness malfunctions, repair wiring harness, then go to the next step.

No

Replace the A/C relay, then go to the next step.

(See RELAY LOCATION.)

15

VERIFY THAT MALFUNCTION SYMPTOMS DO NOT RECUR AFTER REPAIR
  • Does cool air discharge from the vents? (Are the results of refrigerant system performance test normal?)

    (See REFRIGERANT SYSTEM PERFORMANCE TEST.)

Yes

Troubleshooting completed. Explain repairs to customer.

No

Recheck malfunction symptoms, then repeat from Step 1 if malfunction recurs.

< Previous   Next >
 

Free to use workshop manual for your 2015+ Mk4 'ND' Mazda MX-5

COPYRIGHT NOTICE:
This fan site is not affiliated with Mazda, and is intended for personal, or commercial use only. The content of our web pages is for general information purposes only and is presented “as is”. We give no assurance or warranty regarding the accuracy of the contents. Readers should do their due diligence and seek the advice of an appropriately certified automotive technician before attempting any steps on this site. Original content provided by Mazda North America. The content of the manual is copyright under DMCA to: full.metal.resistor@gmail.com
LIMITATION OF LIABILITY:
We accept no responsibility for errors, inaccuracies, or omissions found on these pages. Additionally, we hereby exclude liability for any demands, claims, damages or losses of any kind with regard to any content or information provided on our web-site, including but not limited to incidental or consequential damages, direct or indirect loss, compensatory damages, loss of profits, or otherwise. By using this manual you assume full liablity for any procedures carried out on your vehicle, and are responsible for the vehicle remaining road legal and safe.
Site design © MX5 Docs 2019
Privacy policy
Cookies
X
We use cookies to improve your experience on
our site. By using our site you consent to cookies.
Learn more
I Agree