DETERMINING SHORT TO GROUND LOCATION (HS-CAN)

CAUTION:

  • Perform the following malfunction diagnosis only when it is diagnosed with a short to ground by CONTROLLER AREA NETWORK (CAN) MALFUNCTION DIAGNOSIS FLOW. (See CONTROLLER AREA NETWORK (CAN) MALFUNCTION DIAGNOSIS FLOW.)

System Wiring Diagram

Determination Procedure

CAUTION:

  • When disconnecting the connector, verify that there is no looseness, damage, deformation, corrosion, or poor connection of the connector terminals.

  • When inspecting the DLC-2, touch it with a paper clip or similar thin pin without directly inserting a tester into the terminals.

Step

Inspection

Action

1

INSPECT FOR SHORT TO GROUND BETWEEN BCM AND INSTRUMENT CLUSTER
  • Switch the ignition off.

  • Disconnect the negative battery cable.

    (See NEGATIVE BATTERY CABLE DISCONNECTION/CONNECTION.)

  • Disconnect the connector 2 and 3 which has BCM terminals 3C,3D and 2D,2C.

  • Inspect for continuity at the following terminals:

    • Between DLC-2 terminal F and body ground

    • Between DLC-2 terminal E and body ground

  • Is there continuity?

Yes

Go to Step 8.

No

Go to the next step.

2

INSPECT CAN LINE IN BCM FOR SHORT TO GROUND
  • Inspect for continuity at the following terminals:

    • Between BCM terminal 3C and body ground

    • Between BCM terminal 3D and body ground

  • Is there continuity?

Yes

Replace the BCM because there is a short to ground in the BCM.

(See BODY CONTROL MODULE (BCM) REMOVAL/INSTALLATION.)

No

Go to the next step.

3

INSPECT FOR SHORT TO GROUND BETWEEN CONNECTORS C-38 AND C-39 AND BCM
  • Connect the connector 2 and 3 which has BCM terminals 3C,3D and 2D,2C.

  • Disconnect the connectors C-38 and C-39.

  • Inspect for continuity at the following terminals:

    • Between DLC-2 terminal F and body ground

    • Between DLC-2 terminal E and body ground

  • Is there continuity?

Yes

Repair or replace the wiring harness between the connectors C-38 and C-39 and BCM because the wiring harness is shorted to ground.

No

Go to the next step.

4

INSPECT CAN LINE IN DSC HU/CM FOR SHORT TO GROUND
  • Disconnect the DSC HU/CM connector.

  • Inspect for continuity at the following terminals:

    • Between DSC HU/CM terminal C (wiring harness side) and body ground

    • Between DSC HU/CM terminal D (wiring harness side) and body ground

  • Is there continuity?

Yes

Go to the next step.

No

Replace the DSC HU/CM because there is a short to ground in the DSC HU/CM.

(See DSC HU/CM REMOVAL/INSTALLATION.)

5

INSPECT CAN LINE IN EVP CONTROL UNIT FOR SHORT TO GROUND
  • Disconnect the EVP control unit connector.

  • Inspect for continuity at the following terminals:

    • Between EVP control unit terminal AD (wiring harness side) and body ground

    • Between EVP control unit terminal Z (wiring harness side) and body ground

  • Is there continuity?

Yes

Go to the next step.

No

Replace the EVP control unit because there is a short to ground in the EVP control unit.

(See EVP CONTROL UNIT REMOVAL/INSTALLATION.)

6

INSPECT CAN LINE IN EPS CONTROL MODULE FOR SHORT TO GROUND
  • Disconnect the EPS control module connector.

  • Inspect for continuity at the following terminals:

    • Between EPS control module terminal 2B (wiring harness side) and body ground

    • Between EPS control module terminal 2C (wiring harness side) and body ground

  • Is there continuity?

Yes

Go to the next step.

No

Replace the EPS control module because there is a short to ground in the EPS control module.

(See STEERING WHEEL AND COLUMN REMOVAL/INSTALLATION.)

7

INSPECT CAN LINE IN PCM FOR SHORT TO GROUND
  • Disconnect the PCM connector.

  • Inspect for continuity at the following terminals:

    • Between PCM terminal 2AK (wiring harness side) and body ground

    • Between PCM terminal 2AL (wiring harness side) and body ground

  • Is there continuity?

Yes

Repair or replace the wiring harness between the PCM and connectors C-38 and C-39 because the wiring harness is shorted to ground.

No

Replace the PCM because there is a short to ground in the PCM.

(See PCM REMOVAL/INSTALLATION [SKYACTIV-G 2.0].)

8

INSPECT FOR SHORT TO GROUND BETWEEN CONNECTOR C-42 AND INSTRUMENT CLUSTER
  • Disconnect the connector C-42.

  • Inspect for continuity at the following terminals:

    • Between DLC-2 terminal F and body ground

    • Between DLC-2 terminal E and body ground

  • Is there continuity?

Yes

Go to Step 12.

No

Go to the next step.

9

INSPECT FOR SHORT TO GROUND BETWEEN AUDIO AMPLIFIER AND CONNECTOR C-42
  • Inspect for continuity at the following terminals:

    • Between audio amplifier terminal 2L and body ground

    • Between audio amplifier terminal 2N and body ground

  • Is there continuity?

Yes

Go to the next step.

No

Go to Step 11.

10

INSPECT CAN LINE IN AUDIO AMPLIFIER FOR SHORT TO GROUND
  • Disconnect the audio amplifier connector.

  • Inspect for continuity at the following terminals:

    • Between audio amplifier terminal 2L (wiring harness side) and body ground

    • Between audio amplifier terminal 2N (wiring harness side) and body ground

  • Is there continuity?

Yes

Repair or replace the wiring harness between the audio amplifier and connector C-42 because the wiring harness is shorted to ground.

No

Replace the audio amplifier because there is a short to ground in the audio amplifier.

(See AUDIO AMPLIFIER REMOVAL/INSTALLATION.)

11

INSPECT CAN LINE IN TCM FOR SHORT TO GROUND
  • Disconnect the TCM connector.

  • Inspect for continuity at the following terminals:

    • Between TCM terminal 2G (wiring harness side) and body ground

    • Between TCM terminal 2C (wiring harness side) and body ground

  • Is there continuity?

Yes

Repair or replace the wiring harness between the TCM and connector C-42 and BCM because the wiring harness is shorted to ground.

No

Replace the TCM because there is a short to ground in the TCM.

(See CONTROL VALVE BODY REMOVAL [SJ6A-EL].)

(See CONTROL VALVE BODY INSTALLATION [SJ6A-EL].)

12

INSPECT FOR SHORT TO GROUND BETWEEN CONNECTOR C-25 AND INSTRUMENT CLUSTER
  • Disconnect the connector C-25.

  • Inspect for continuity at the following terminals:

    • Between DLC-2 terminal F and body ground

    • Between DLC-2 terminal E and body ground

  • Is there continuity?

Yes

Go to Step 15.

No

Go to the next step.

13

INSPECT FOR SHORT TO GROUND BETWEEN CONNECTOR C-30 AND CONNECTOR C-42 AND CONNECTOR C-25
  • Disconnect the connector C-30.

  • Inspect for continuity at the following terminals:

    • Between occupant classification sensor terminal 4B and body ground

    • Between occupant classification sensor terminal 4A and body ground

  • Is there continuity?

Yes

Go to the next step.

No

Repair or replace the wiring harness between the connector C-30 and connector C-42 and connector C-25 because the wiring harness is shorted to ground.

14

INSPECT CAN LINE IN OCCUPANT CLASSIFICATION SENSOR FOR SHORT TO GROUND
  • Disconnect the occupant classification sensor connector.

  • Inspect for continuity at the following terminals:

    • Between occupant classification sensor terminal 4B (wiring harness side) and body ground

    • Between occupant classification sensor terminal 4A (wiring harness side) and body ground

  • Is there continuity?

Yes

Repair or replace the wiring harness between the occupant classification sensor and connector C-30 because the wiring harness is shorted to ground.

No

Replace the occupant classification sensor because there is a short to ground in the occupant classification sensor.

(See OCCUPANT CLASSIFICATION SENSOR REMOVAL/INSTALLATION [TWO-STEP DEPLOYMENT CONTROL SYSTEM].)

15

INSPECT FOR SHORT TO GROUND BETWEEN CONNECTOR C-14 AND INSTRUMENT CLUSTER
  • Disconnect the connector C-14.

  • Inspect for continuity at the following terminals:

    • Between DLC-2 terminal F and body ground

    • Between DLC-2 terminal E and body ground

  • Is there continuity?

Yes

Go to the next step.

No

Repair or replace the wiring harness between the connector C-25 and connector C-14 because the wiring harness is shorted to ground.

16

INSPECT FOR SHORT TO GROUND BETWEEN CONNECTOR C-17 AND INSTRUMENT CLUSTER
  • Disconnect the connector C-17.

  • Inspect for continuity at the following terminals:

    • Between DLC-2 terminal F and body ground

    • Between DLC-2 terminal E and body ground

  • Is there continuity?

Yes

Go to Step 19.

No

Go to the next step.

17

INSPECT FOR SHORT TO GROUND BETWEEN FORWARD SENSING CAMERA (FSC) AND CONNECTOR C-17
  • Inspect for continuity at the following terminals:

    • Between forward sensing camera (FSC) terminal E and body ground

    • Between forward sensing camera (FSC) terminal C and body ground

  • Is there continuity?

Yes

Go to the next step.

No

Repair or replace the wiring harness between the connector C-14 and connector C-17 because the wiring harness is shorted to ground.

18

INSPECT CAN LINE IN FORWARD SENSING CAMERA (FSC) FOR SHORT TO GROUND
  • Disconnect the forward sensing camera (FSC) connector.

  • Inspect for continuity at the following terminals:

    • Between forward sensing camera (FSC) terminal E (wiring harness side) and body ground

    • Between forward sensing camera (FSC) terminal C (wiring harness side) and body ground

  • Is there continuity?

Yes

Repair or replace the wiring harness between the forward sensing camera (FSC) and connector C-17 because the wiring harness is shorted to ground.

No

Replace the forward sensing camera (FSC) because there is a short to ground in the forward sensing camera (FSC).

(See FORWARD SENSING CAMERA (FSC) REMOVAL/INSTALLATION.)

19

INSPECT FOR SHORT TO GROUND BETWEEN CONNECTOR C-41 AND DLC-2
  • Disconnect the connector C-41.

  • Inspect for continuity at the following terminals:

    • Between DLC-2 terminal F and body ground

    • Between DLC-2 terminal E and body ground

  • Is there continuity?

Yes

Repair or replace the wiring harness between the connector C-41 and DLC-2 because the wiring harness is shorted to ground.

No

Go to the next step.

20

INSPECT FOR SHORT TO GROUND BETWEEN AFS CONTROL MODULE / AUTO LEVELING CONTROL MODULE AND CONNECTOR C-17 AND CONNECTOR C-41
  • Inspect for continuity at the following terminals:

    • Between AFS control module / auto leveling control module terminal A and body ground

    • Between AFS control module / auto leveling control module terminal B and body ground

  • Is there continuity?

Yes

Go to the next step.

No

Go to Step 22.

21

INSPECT CAN LINE IN AFS CONTROL MODULE / AUTO LEVELING CONTROL MODULE FOR SHORT TO GROUND
  • Disconnect the AFS control module / auto leveling control module connector.

  • Inspect for continuity at the following terminals:

    • Between AFS control module / auto leveling control module terminal A (wiring harness side) and body ground

    • Between AFS control module / auto leveling control module terminal B (wiring harness side) and body ground

  • Is there continuity?

Yes

Repair or replace the wiring harness between the AFS control module / auto leveling control module and connector C-17 and connector C-41 because the wiring harness is shorted to ground.

No

Replace the AFS control module / auto leveling control module because there is a short to ground in the AFS control module / auto leveling control module.

(See AUTO LEVELING CONTROL MODULE REMOVAL/INSTALLATION.)

(See ADAPTIVE FRONT LIGHTING SYSTEM (AFS) CONTROL MODULE REMOVAL/INSTALLATION.)

22

INSPECT FOR SHORT TO GROUND BETWEEN START STOP UNIT AND CONNECTOR C-41
  • Inspect for continuity at the following terminals:

    • Between start stop unit terminal 2M and body ground

    • Between start stop unit terminal 2O and body ground

  • Is there continuity?

Yes

Go to the next step.

No

Go to Step 25.

23

INSPECT FOR SHORT TO GROUND BETWEEN START STOP UNIT AND CONNECTOR C-19
  • Disconnect the connector C-19.

  • Inspect for continuity at the following terminals:

    • Between start stop unit terminal 2M and body ground

    • Between start stop unit terminal 2O and body ground

  • Is there continuity?

Yes

Go to the next step.

No

Repair or replace the wiring harness between the connector C-19 and connector C-41 because the wiring harness is shorted to ground.

24

INSPECT CAN LINE IN START STOP UNIT FOR SHORT TO GROUND
  • Disconnect the start stop unit connector.

  • Inspect for continuity at the following terminals:

    • Between start stop unit terminal 2M (wiring harness side) and body ground

    • Between start stop unit terminal 2O (wiring harness side) and body ground

  • Is there continuity?

Yes

Repair or replace the wiring harness between the start stop unit and connector C-19 because the wiring harness is shorted to ground.

No

Replace the start stop unit because there is a short to ground in the start stop unit.

(See START STOP UNIT REMOVAL/INSTALLATION.)

25

INSPECT FOR SHORT TO GROUND BETWEEN CONNECTIVITY MASTER UNIT (CMU) AND CONNECTOR C-41
  • Inspect for continuity at the following terminals:

    • Between connectivity master unit (CMU) terminal 2E and body ground

    • Between connectivity master unit (CMU) terminal 2F and body ground

  • Is there continuity?

Yes

Go to the next step.

No

Go to Step 27.

26

INSPECT CAN LINE IN CONNECTIVITY MASTER UNIT (CMU) FOR SHORT TO GROUND
  • Disconnect the connectivity master unit (CMU) connector.

  • Inspect for continuity at the following terminals:

    • Between connectivity master unit (CMU) terminal 2E (wiring harness side) and body ground

    • Between connectivity master unit (CMU) terminal 2F (wiring harness side) and body ground

  • Is there continuity?

Yes

Repair or replace the wiring harness between the connectivity master unit (CMU) and connector C-41 because the wiring harness is shorted to ground.

No

Replace the connectivity master unit (CMU) because there is a short to ground in the connectivity master unit (CMU).

(See CONNECTIVITY MASTER UNIT (CMU) REMOVAL/INSTALLATION.)

27

INSPECT FOR SHORT TO GROUND BETWEEN SAS CONTROL MODULE AND CONNECTOR C-41
  • Inspect for continuity at the following terminals:

    • Between SAS control module terminal 3Q and body ground

    • Between SAS control module terminal 3S and body ground

  • Is there continuity?

Yes

Go to the next step.

No

Go to Step 29.

28

INSPECT CAN LINE IN SAS CONTROL MODULE FOR SHORT TO GROUND
  • Disconnect the SAS control module connector.

  • Inspect for continuity at the following terminals:

    • Between SAS control module terminal 3Q (wiring harness side) and body ground

    • Between SAS control module terminal 3S (wiring harness side) and body ground

  • Is there continuity?

Yes

Repair or replace the wiring harness between the SAS control module and connector C-41 because the wiring harness is shorted to ground.

No

Replace the SAS control module because there is a short to ground in the SAS control module.

(See SAS CONTROL MODULE REMOVAL/INSTALLATION [TWO-STEP DEPLOYMENT CONTROL SYSTEM].)

(See SAS CONTROL MODULE REMOVAL/INSTALLATION [STANDARD DEPLOYMENT CONTROL SYSTEM].)

29

INSPECT CAN LINE IN INSTRUMENT CLUSTER FOR SHORT TO GROUND
  • Disconnect the instrument cluster connector.

  • Inspect for continuity at the following terminals:

    • Between instrument cluster terminal B (wiring harness side) and body ground

    • Between instrument cluster terminal D (wiring harness side) and body ground

  • Is there continuity?

Yes

Repair or replace the wiring harness between the instrument cluster and connector C-41 because the wiring harness is shorted to ground.

No

Replace the instrument cluster because there is a short to ground in the instrument cluster.

(See INSTRUMENT CLUSTER REMOVAL/INSTALLATION.)

< Previous   Next >
 

Free to use workshop manual for your 2015+ Mk4 'ND' Mazda MX-5

COPYRIGHT NOTICE:
This fan site is not affiliated with Mazda, and is intended for personal, or commercial use only. The content of our web pages is for general information purposes only and is presented “as is”. We give no assurance or warranty regarding the accuracy of the contents. Readers should do their due diligence and seek the advice of an appropriately certified automotive technician before attempting any steps on this site. Original content provided by Mazda North America. The content of the manual is copyright under DMCA to: full.metal.resistor@gmail.com
LIMITATION OF LIABILITY:
We accept no responsibility for errors, inaccuracies, or omissions found on these pages. Additionally, we hereby exclude liability for any demands, claims, damages or losses of any kind with regard to any content or information provided on our web-site, including but not limited to incidental or consequential damages, direct or indirect loss, compensatory damages, loss of profits, or otherwise. By using this manual you assume full liablity for any procedures carried out on your vehicle, and are responsible for the vehicle remaining road legal and safe.
Site design © MX5 Docs 2019
Privacy policy
Cookies
X
We use cookies to improve your experience on
our site. By using our site you consent to cookies.
Learn more
I Agree