DETERMINING SHORT TO GROUND LOCATION (HS-CAN)
CAUTION:
Perform the following malfunction diagnosis only when it is diagnosed with a short to ground by CONTROLLER AREA NETWORK (CAN) MALFUNCTION DIAGNOSIS FLOW. (See CONTROLLER AREA NETWORK (CAN) MALFUNCTION DIAGNOSIS FLOW.)
System Wiring Diagram
Determination Procedure
CAUTION:
When disconnecting the connector, verify that there is no looseness, damage, deformation, corrosion, or poor connection of the connector terminals.
When inspecting the DLC-2, touch it with a paper clip or similar thin pin without directly inserting a tester into the terminals.
| Step |
Inspection |
Action |
|
| 1 |
INSPECT FOR SHORT TO GROUND BETWEEN BCM AND INSTRUMENT CLUSTER
|
Yes |
Go to Step 8. |
| No |
Go to the next step. |
||
| 2 |
INSPECT CAN LINE IN BCM FOR SHORT TO GROUND
|
Yes |
Replace the BCM because there is a short to ground in the BCM. |
| No |
Go to the next step. |
||
| 3 |
INSPECT FOR SHORT TO GROUND BETWEEN CONNECTORS C-38 AND C-39 AND BCM
|
Yes |
Repair or replace the wiring harness between the connectors C-38 and C-39 and BCM because the wiring harness is shorted to ground. |
| No |
Go to the next step. |
||
| 4 |
INSPECT CAN LINE IN DSC HU/CM FOR SHORT TO GROUND
|
Yes |
Go to the next step. |
| No |
Replace the DSC HU/CM because there is a short to ground in the DSC HU/CM. |
||
| 5 |
INSPECT CAN LINE IN EVP CONTROL UNIT FOR SHORT TO GROUND
|
Yes |
Go to the next step. |
| No |
Replace the EVP control unit because there is a short to ground in the EVP control unit. |
||
| 6 |
INSPECT CAN LINE IN EPS CONTROL MODULE FOR SHORT TO GROUND
|
Yes |
Go to the next step. |
| No |
Replace the EPS control module because there is a short to ground in the EPS control module. |
||
| 7 |
INSPECT CAN LINE IN PCM FOR SHORT TO GROUND
|
Yes |
Repair or replace the wiring harness between the PCM and connectors C-38 and C-39 because the wiring harness is shorted to ground. |
| No |
Replace the PCM because there is a short to ground in the PCM. |
||
| 8 |
INSPECT FOR SHORT TO GROUND BETWEEN CONNECTOR C-42 AND INSTRUMENT CLUSTER
|
Yes |
Go to Step 12. |
| No |
Go to the next step. |
||
| 9 |
INSPECT FOR SHORT TO GROUND BETWEEN AUDIO AMPLIFIER AND CONNECTOR C-42
|
Yes |
Go to the next step. |
| No |
Go to Step 11. |
||
| 10 |
INSPECT CAN LINE IN AUDIO AMPLIFIER FOR SHORT TO GROUND
|
Yes |
Repair or replace the wiring harness between the audio amplifier and connector C-42 because the wiring harness is shorted to ground. |
| No |
Replace the audio amplifier because there is a short to ground in the audio amplifier. |
||
| 11 |
INSPECT CAN LINE IN TCM FOR SHORT TO GROUND
|
Yes |
Repair or replace the wiring harness between the TCM and connector C-42 and BCM because the wiring harness is shorted to ground. |
| No |
Replace the TCM because there is a short to ground in the TCM. |
||
| 12 |
INSPECT FOR SHORT TO GROUND BETWEEN CONNECTOR C-25 AND INSTRUMENT CLUSTER
|
Yes |
Go to Step 15. |
| No |
Go to the next step. |
||
| 13 |
INSPECT FOR SHORT TO GROUND BETWEEN CONNECTOR C-30 AND CONNECTOR C-42 AND CONNECTOR C-25
|
Yes |
Go to the next step. |
| No |
Repair or replace the wiring harness between the connector C-30 and connector C-42 and connector C-25 because the wiring harness is shorted to ground. |
||
| 14 |
INSPECT CAN LINE IN OCCUPANT CLASSIFICATION SENSOR FOR SHORT TO GROUND
|
Yes |
Repair or replace the wiring harness between the occupant classification sensor and connector C-30 because the wiring harness is shorted to ground. |
| No |
Replace the occupant classification sensor because there is a short to ground in the occupant classification sensor. (See OCCUPANT CLASSIFICATION SENSOR REMOVAL/INSTALLATION [TWO-STEP DEPLOYMENT CONTROL SYSTEM].) |
||
| 15 |
INSPECT FOR SHORT TO GROUND BETWEEN CONNECTOR C-14 AND INSTRUMENT CLUSTER
|
Yes |
Go to the next step. |
| No |
Repair or replace the wiring harness between the connector C-25 and connector C-14 because the wiring harness is shorted to ground. |
||
| 16 |
INSPECT FOR SHORT TO GROUND BETWEEN CONNECTOR C-17 AND INSTRUMENT CLUSTER
|
Yes |
Go to Step 19. |
| No |
Go to the next step. |
||
| 17 |
INSPECT FOR SHORT TO GROUND BETWEEN FORWARD SENSING CAMERA (FSC) AND CONNECTOR C-17
|
Yes |
Go to the next step. |
| No |
Repair or replace the wiring harness between the connector C-14 and connector C-17 because the wiring harness is shorted to ground. |
||
| 18 |
INSPECT CAN LINE IN FORWARD SENSING CAMERA (FSC) FOR SHORT TO GROUND
|
Yes |
Repair or replace the wiring harness between the forward sensing camera (FSC) and connector C-17 because the wiring harness is shorted to ground. |
| No |
Replace the forward sensing camera (FSC) because there is a short to ground in the forward sensing camera (FSC). |
||
| 19 |
INSPECT FOR SHORT TO GROUND BETWEEN CONNECTOR C-41 AND DLC-2
|
Yes |
Repair or replace the wiring harness between the connector C-41 and DLC-2 because the wiring harness is shorted to ground. |
| No |
Go to the next step. |
||
| 20 |
INSPECT FOR SHORT TO GROUND BETWEEN AFS CONTROL MODULE / AUTO LEVELING CONTROL MODULE AND CONNECTOR C-17 AND CONNECTOR C-41
|
Yes |
Go to the next step. |
| No |
Go to Step 22. |
||
| 21 |
INSPECT CAN LINE IN AFS CONTROL MODULE / AUTO LEVELING CONTROL MODULE FOR SHORT TO GROUND
|
Yes |
Repair or replace the wiring harness between the AFS control module / auto leveling control module and connector C-17 and connector C-41 because the wiring harness is shorted to ground. |
| No |
Replace the AFS control module / auto leveling control module because there is a short to ground in the AFS control module / auto leveling control module. (See AUTO LEVELING CONTROL MODULE REMOVAL/INSTALLATION.) (See ADAPTIVE FRONT LIGHTING SYSTEM (AFS) CONTROL MODULE REMOVAL/INSTALLATION.) |
||
| 22 |
INSPECT FOR SHORT TO GROUND BETWEEN START STOP UNIT AND CONNECTOR C-41
|
Yes |
Go to the next step. |
| No |
Go to Step 25. |
||
| 23 |
INSPECT FOR SHORT TO GROUND BETWEEN START STOP UNIT AND CONNECTOR C-19
|
Yes |
Go to the next step. |
| No |
Repair or replace the wiring harness between the connector C-19 and connector C-41 because the wiring harness is shorted to ground. |
||
| 24 |
INSPECT CAN LINE IN START STOP UNIT FOR SHORT TO GROUND
|
Yes |
Repair or replace the wiring harness between the start stop unit and connector C-19 because the wiring harness is shorted to ground. |
| No |
Replace the start stop unit because there is a short to ground in the start stop unit. |
||
| 25 |
INSPECT FOR SHORT TO GROUND BETWEEN CONNECTIVITY MASTER UNIT (CMU) AND CONNECTOR C-41
|
Yes |
Go to the next step. |
| No |
Go to Step 27. |
||
| 26 |
INSPECT CAN LINE IN CONNECTIVITY MASTER UNIT (CMU) FOR SHORT TO GROUND
|
Yes |
Repair or replace the wiring harness between the connectivity master unit (CMU) and connector C-41 because the wiring harness is shorted to ground. |
| No |
Replace the connectivity master unit (CMU) because there is a short to ground in the connectivity master unit (CMU). |
||
| 27 |
INSPECT FOR SHORT TO GROUND BETWEEN SAS CONTROL MODULE AND CONNECTOR C-41
|
Yes |
Go to the next step. |
| No |
Go to Step 29. |
||
| 28 |
INSPECT CAN LINE IN SAS CONTROL MODULE FOR SHORT TO GROUND
|
Yes |
Repair or replace the wiring harness between the SAS control module and connector C-41 because the wiring harness is shorted to ground. |
| No |
Replace the SAS control module because there is a short to ground in the SAS control module. (See SAS CONTROL MODULE REMOVAL/INSTALLATION [TWO-STEP DEPLOYMENT CONTROL SYSTEM].) (See SAS CONTROL MODULE REMOVAL/INSTALLATION [STANDARD DEPLOYMENT CONTROL SYSTEM].) |
||
| 29 |
INSPECT CAN LINE IN INSTRUMENT CLUSTER FOR SHORT TO GROUND
|
Yes |
Repair or replace the wiring harness between the instrument cluster and connector C-41 because the wiring harness is shorted to ground. |
| No |
Replace the instrument cluster because there is a short to ground in the instrument cluster. |
||